{"product_id":"tomzn-toq5-160-4p-handle-type-160a-4p-ac-three-phase-dual-power-automatic-transfer-switch-ats","title":"Tomzn TOQ5-160\/4P Handle Type 160A 4P AC Three Phase Dual Power Automatic Transfer Switch ATS","description":"\u003cdiv class=\"module_title\"\u003e\n\u003cdiv class=\"product-title-container\" data-aplus-ae=\"x1_77a36ef7\" data-spm-anchor-id=\"a2700.details.0.i1.70bff51c9zLDbM\"\u003e\n\u003ch3 data-start=\"148\" data-end=\"254\"\u003e\u003cstrong data-start=\"152\" data-end=\"252\"\u003eTomzn TOQ5-160\/4P Handle Type | 160A 4-Pole 3-Phase Dual Power Automatic Transfer Switch (ATS)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"255\" data-end=\"314\"\u003e\u003cstrong data-start=\"255\" data-end=\"314\"\u003eHeavy-Duty Power Switching – Manual \u0026amp; Automatic Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"316\" data-end=\"651\"\u003eThe Tomzn \u003cstrong\u003eTOQ5-160\/4P\u003c\/strong\u003e\u003cstrong data-start=\"320\" data-end=\"355\"\u003e Handle Type\u003c\/strong\u003e Automatic Transfer Switch is built for high-load applications requiring fast and reliable power source switching between main and backup supplies. With a \u003cstrong data-start=\"510\" data-end=\"525\"\u003e160A rating\u003c\/strong\u003e and \u003cstrong data-start=\"530\" data-end=\"555\"\u003e4-pole 3-phase design\u003c\/strong\u003e, it’s perfect for factories, commercial buildings, and solar or generator-based backup systems.\u003c\/p\u003e\n\u003cp data-start=\"653\" data-end=\"803\"\u003eThis model features a \u003cstrong data-start=\"675\" data-end=\"701\"\u003emanual override handle\u003c\/strong\u003e, providing full control in critical scenarios along with \u003cstrong data-start=\"761\" data-end=\"774\"\u003eauto mode\u003c\/strong\u003e for uninterrupted operation.\u003c\/p\u003e\n\u003ch4 data-start=\"805\" data-end=\"844\"\u003e Key Features \u0026amp; Technical Specs:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"847\" data-end=\"874\"\u003e\n\u003cstrong data-start=\"847\" data-end=\"857\"\u003eModel:\u003c\/strong\u003e TOQ5-160\/4P\u003c\/li\u003e\n\u003cli data-start=\"877\" data-end=\"894\"\u003e\n\u003cstrong data-start=\"877\" data-end=\"887\"\u003eBrand:\u003c\/strong\u003e TOMZN\u003c\/li\u003e\n\u003cli data-start=\"897\" data-end=\"923\"\u003e\n\u003cstrong data-start=\"897\" data-end=\"916\"\u003eCurrent Rating:\u003c\/strong\u003e 160A\u003c\/li\u003e\n\u003cli data-start=\"926\" data-end=\"961\"\u003e\n\u003cstrong data-start=\"926\" data-end=\"936\"\u003ePoles:\u003c\/strong\u003e 4P (3-phase + neutral)\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1023\"\u003e\n\u003cstrong data-start=\"964\" data-end=\"982\"\u003eRated Voltage:\u003c\/strong\u003e 400V AC | \u003cstrong data-start=\"993\" data-end=\"1013\"\u003eControl Voltage:\u003c\/strong\u003e 220V AC\u003c\/li\u003e\n\u003cli data-start=\"1026\" data-end=\"1050\"\u003e\n\u003cstrong data-start=\"1026\" data-end=\"1040\"\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli data-start=\"1053\" data-end=\"1086\"\u003e\n\u003cstrong data-start=\"1053\" data-end=\"1076\"\u003eInsulation Voltage:\u003c\/strong\u003e 800V AC\u003c\/li\u003e\n\u003cli data-start=\"1089\" data-end=\"1125\"\u003e\n\u003cstrong data-start=\"1089\" data-end=\"1119\"\u003eImpulse Withstand Voltage:\u003c\/strong\u003e 6kV\u003c\/li\u003e\n\u003cli data-start=\"1128\" data-end=\"1162\"\u003e\n\u003cstrong data-start=\"1128\" data-end=\"1147\"\u003eSwitching Time:\u003c\/strong\u003e \u0026lt;2.5 seconds\u003c\/li\u003e\n\u003cli data-start=\"1165\" data-end=\"1185\"\u003e\n\u003cstrong data-start=\"1165\" data-end=\"1183\"\u003eControl Modes:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli data-start=\"1190\" data-end=\"1257\"\u003e\n\u003cstrong data-start=\"1190\" data-end=\"1208\"\u003eAutomatic Mode\u003c\/strong\u003e – switches automatically based on power status\u003c\/li\u003e\n\u003cli data-start=\"1262\" data-end=\"1311\"\u003e\n\u003cstrong data-start=\"1262\" data-end=\"1277\"\u003eManual Mode\u003c\/strong\u003e – control via integrated handle\u003cstrong data-start=\"1314\" data-end=\"1325\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1438\" data-end=\"1459\"\u003eHow It Works:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1462\" data-end=\"1534\"\u003ePrioritizes \u003cstrong data-start=\"1474\" data-end=\"1490\"\u003eNormal Power\u003c\/strong\u003e; switches to \u003cstrong data-start=\"1504\" data-end=\"1520\"\u003eBackup Power\u003c\/strong\u003e when needed\u003c\/li\u003e\n\u003cli data-start=\"1537\" data-end=\"1598\"\u003e\n\u003cstrong data-start=\"1537\" data-end=\"1554\"\u003eManual handle\u003c\/strong\u003e allows override in emergencies or testing\u003c\/li\u003e\n\u003cli data-start=\"1601\" data-end=\"1703\"\u003eBrief interruption during transfer (\u0026lt;2.5s); not suitable for sensitive loads unless protected by UPS\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1753\"\u003eDoes \u003cstrong data-start=\"1711\" data-end=\"1753\"\u003enot control generator startup\/shutdown\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e⚠️ Ideal for use with generators, solar inverters, or dual-grid sources in residential, commercial, or industrial settings.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tomzn","offers":[{"title":"Default Title","offer_id":49412170154212,"sku":"AR-002446","price":29199.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/2840\/2660\/files\/TOQ5-160A-4P_5.jpg?v=1784136016","url":"https:\/\/gammaenergy.pk\/products\/tomzn-toq5-160-4p-handle-type-160a-4p-ac-three-phase-dual-power-automatic-transfer-switch-ats","provider":"Gamma Energy","version":"1.0","type":"link"}