{"product_id":"cnc-yc7va-4-pole-3-phase-voltage-and-current-protector","title":"CNC YC7VA 4 Pole 3 Phase Voltage And Current Protector","description":"\u003ch3\u003e\u003cstrong\u003eCNC YC9VA-3 4Pole 3 Phase Voltage and Current Protector\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCNC YC9VA-3 4Pole 3 Phase Voltage and Current Protector\u003c\/strong\u003e is designed to safeguard electrical systems by offering comprehensive protection against over-voltage, under-voltage, over-current, and phase imbalances. It provides an adjustable solution for managing power quality in 3-phase systems, ensuring the safety and reliability of connected equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-voltage Protection\u003c\/strong\u003e: Adjustable range of \u003cstrong\u003e230V to 300V\u003c\/strong\u003e, preventing damage from voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder-voltage Protection\u003c\/strong\u003e: Adjustable range of \u003cstrong\u003e120V to 210V\u003c\/strong\u003e, protecting systems from low voltage conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Current Protection\u003c\/strong\u003e: Adjustable range of \u003cstrong\u003e5A to 63A\u003c\/strong\u003e, ensuring circuits are safeguarded from excessive current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsymmetry Protection\u003c\/strong\u003e: Detects phase imbalance and prevents operational issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Sequence Protection\u003c\/strong\u003e: Ensures proper phase rotation to prevent equipment damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Timing\u003c\/strong\u003e: \u003cstrong\u003eActive time\u003c\/strong\u003e and \u003cstrong\u003ereconnect time\u003c\/strong\u003e can be set for optimal system management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Calibration\u003c\/strong\u003e: Allows for manual calibration of \u003cstrong\u003evoltage\u003c\/strong\u003e and \u003cstrong\u003ecurrent\u003c\/strong\u003e for accurate readings and control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Power Supply Voltage\u003c\/strong\u003e: \u003cstrong\u003eAC 230V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: \u003cstrong\u003e50\/60Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Adjustment Range\u003c\/strong\u003e: \u003cstrong\u003e230V~300V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Voltage Adjustment Range\u003c\/strong\u003e: \u003cstrong\u003e120V~210V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Adjustment Range\u003c\/strong\u003e: \u003cstrong\u003e5A~63A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Unbalance Fault Delay\u003c\/strong\u003e: \u003cstrong\u003e10s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Fault Delay\u003c\/strong\u003e: \u003cstrong\u003e5s~600s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Fault Delay\u003c\/strong\u003e: \u003cstrong\u003e0s~10s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Fault Delay\u003c\/strong\u003e: \u003cstrong\u003e0s~10s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltmeter Accuracy\u003c\/strong\u003e: \u003cstrong\u003e1%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e: \u003cstrong\u003e450V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating\u003c\/strong\u003e: \u003cstrong\u003eIP20\u003c\/strong\u003e (Protection against dust and water ingress)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Life\u003c\/strong\u003e: \u003cstrong\u003e100,000 operations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Life\u003c\/strong\u003e: \u003cstrong\u003e1,000,000 operations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: \u003cstrong\u003e-5°C to +50°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: \u003cstrong\u003e-40°C to +55°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Compatible with \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e for easy installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003eCNC YC9VA-3 4Pole 3 Phase Voltage and Current Protector\u003c\/strong\u003e is an essential protection device for industrial and commercial applications where maintaining stable power supply is crucial. It ensures long-lasting protection for electrical systems and enhances operational reliability.\u003c\/p\u003e\n\u003ctable height=\"534\" style=\"border-collapse: collapse; width: 542px;\" width=\"500\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 316px;\" width=\"296\"\u003e \u003ccol style=\"width: 225px;\" width=\"204\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 222pt;\" width=\"296\" class=\"xl63\" height=\"20\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 153pt;\" width=\"204\" class=\"xl63\"\u003e\u003cstrong\u003eData\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eRated power supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003eAC230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eMaximum voltage adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e230V~300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eMinimum voltage adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e120V-210V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eRange of adjustment of the maximum current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e5A~63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eDeviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eDelay time of phase unbalance fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eDelay time of overcurrent fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e5s~600s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eDelay time of closing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e5s~600s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eDelay time of overvoltage fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003eOs~10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eDelay time of undervoltage fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003eOs 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eLag voltage of overvoltage and undervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003eOV~15V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eVoltmeter accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eRated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eOutput contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e30N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003ePollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eElectrical life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e100000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e1000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e≤2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e-5°C~+50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e50% at 40°C(non-condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.3125px;\"\u003e-40°C~+55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 20.5px;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"CNC Electric","offers":[{"title":"63A YC7VA","offer_id":49412199842020,"sku":"AR-001267","price":6950.0,"currency_code":"PKR","in_stock":true},{"title":"100A YC7VA","offer_id":49412199874788,"sku":"AR-002456","price":7790.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/2840\/2660\/files\/F_8ab79ed1-f9b2-46e3-98b4-e8b5d1107f71.jpg?v=1784136171","url":"https:\/\/gammaenergy.pk\/products\/cnc-yc7va-4-pole-3-phase-voltage-and-current-protector","provider":"Gamma Energy","version":"1.0","type":"link"}